10Hz-300kHz Benchtop Digital LCR Meter SCPI Instruction Set
Part No.: LCRM-AT2818
Main Features:
- TFT-LCD Display;Cearly shows all measurments parameters.
- With Open and short correction options.
- Comparator Function: 10 files,14 bins: P1~P9,NG,AUX, HI, IN, LO
- Interface: RS232C Easy to be connected to PC with USB and handler Interface;
- High accuracy: 0.05%+5
- Key lock function
- Test signal monitor: Vm and Im;Avarage rate: 1~200times
- Measurement Terminal: 5 terminals;
• Parameters:Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,Rs-Q,R-X,Z-θrad,Z-θdeg
• Monitor Parameters:Z, D, Q, θr, θd, R, X, G, B, Y, Vac, Iac, Δ, Δ%
• Accuracy:0.05% ±5
• Frequency:10Hz~300kHz(continuous frequency, frequency resolution 0.001Hz)
• Display Range
L: 0.00001μH-999999H
C: 0.00001pF – 999999μF
R,Z: 0.00001Ω – 99.9999MΩ
D,Q: 0.00001 – 999999
Θ(deg): -179.999 ° -179.999 °
Θ(rad) : -3.14159 – 3.14159
Δ%: -999999% – 999999%
• Source Resistance:30Ω, 50Ω, 100Ω
• Range:Automatic, Manual, and nominal, 9 ranges
• Display Max:6 digital, principle parameter: 999999; sub parameter:999999; monitor parameter: 999999
• Signal Level:0.01V – 2.00V (10mV Step)
• Speed:30t/s, 10t/s, 6 t/s, 3 t/s 1-256 times average is available
• Comparator:14-bin sorting, 10-bin GD, 1-bin NG, 1-bin AUX,2-bin principle parameter NG; Count Function: Max – 999999
• List Scanning:10 group frequency and level scanning measurement
• Adjustment:Open & Short circuit sweep frequency reset,3 point frequency reset and load calibration.
• Files:10 group files to save user’s setting, 1 group to save system data real-time
• Interface:RS232C, ExHandler interface,standard configuration USB Disc interface (article 10000 data)
• Others:LCR Automatic selection, keypad lock,SCPI instruction set, true-color TFT-LCD Display
• Power Supply
Voltage: 90V AC – 250V AC Frequency: 50Hz – 60Hz Max Power: 20VA
• Dimension & Weight:264mm (width)x107mm(height)x350mm(depth) 4kg
• What is in the package:
ATL501: Test cable
ATL607: Test Fixture
ATL600: Short-circuit device
ATL801: 232 Communication cable
Parameters | Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q, Rs-Q, R-X, Z-θrad, Z -θdeg |
Monitoring Parameters | Z, D, Q, θr, θd, R, X, G, B, Y, Vac, Iac, Δ, Δ% |
Accuracy | 0.05% ± 5 dgt |
Frequency | 10Hz – 300kHz (continuous frequency, frequency resolution 0.001Hz |
Display Range | L: 0.00001μH to 999999H C: 0.00001pF to 999999μF R, Z: 0.00001Ω to 99.9999MΩ D: 0.00001 to 9.99999 Q: 0.00001 to 99999.9 Δ%: -999999% to 999999% θdeg: -179.999° to 179.999° θrad: -3.14159 to 3.14159 |
Source Resistance | 30, 50 and 100Ω |
Range | Automatic, manual and nominal 9 ranges |
Display Max | 6 digital, principle parameter: 999999 Sub parameter: 999999 Monitor parameter: 999999 |
Signal Level | 0.01V to 2.00V (10mV steps) |
Speed | 30t/s, 10t/s, 6 t/s, 3 t/s 1 – 256 average is available |
Comparator | 14-bin sorting, 10-bin GD, 1-bin NG, 1-bin AUX, 2-bin principle parameters NG; count function: MAX – 999999 |
List Test | 10 ground frequency and level scanning measurement |
Adjustments | Open and short circuit sweep frequency reset, 3 point frequency reset and load calibration |
Files | 10 group files to save user’s settings, 1 group to save system data in real-time |
Interfaces | RS232C, EXHandler, standard configuration USB Disc interface (article 10000 data) |
Other Information | LCR Automatic selection, keypad lock, SCPI instruction set, true-colour TFT LCD display |
General Specs | |
Power Supply | Voltage: 90V AC – 250V AC Frequency: 50Hz – 60Hz Max Power: 20VA |
Size | 264mm (width) x 107mm (height) x 350mm (depth) Weight: 4kg |
Measurement Speed